Type byte-address inputs of the two-stage RLE lookup helpers
Ghidra v1809 · 383dd74
Each independently inspected helper captures two integer arguments as byte lookup-table addresses and computes table1[table2[sourceByte]]. Table numbers follow their exact unchanged upstream API identities, not execution order. The clipped helper additionally uses incoming EDX as its byte-output address. Correct all five integer address representations and generic names coherently; preserve existing byte-buffer/scalar inputs, chosen names, void results, fastcall arity/storage and RET16/RET28. Table inputs are captured in EDI/ESI before reused stack locations become scratch. No sibling inference or allocation extent assumed.
Changes 10, applied together
Retype variable
win 0x006072f0 Stack[0xc]typeint32_t→uint8_t *Rename variable
win 0x006072f0 Stack[0xc]namenParam1→pLookupTable1Retype variable
win 0x006072f0 Stack[0x10]typeint32_t→uint8_t *Rename variable
win 0x006072f0 Stack[0x10]namenParam2→pLookupTable2Retype variable
win 0x00607480 EDXtypeint32_t→uint8_t *Rename variable
win 0x00607480 EDXnamenParam1→pDstBufferRetype variable
win 0x00607480 Stack[0x18]typeint32_t→uint8_t *Rename variable
win 0x00607480 Stack[0x18]namenParam5→pLookupTable1Retype variable
win 0x00607480 Stack[0x1c]typeint32_t→uint8_t *Rename variable
win 0x00607480 Stack[0x1c]namenParam6→pLookupTable2